Solar takeoff software: roof planes, arrays and cable runs
Solar takeoffs start on the roof plan: the roof planes that can take panels, the array area and panel count, the rails, and the DC and AC cable back to the inverter, battery and isolators. TrueScale™ measures each plane, sets its pitch, and counts the equipment.
Start free trial 30 days, every feature, no card
What solar installers measure, and why
- Usable roof planes as areas at their pitch, because panels sit on the real roof surface, not the plan.
- Panels as a count and the array as an area, so one can be checked against the other.
- Mounting rail, DC and AC cable and conduit as lengths.
- Inverters, batteries and DC and AC isolators as counts.
The Solar tool set
10 tools, from Tool Shed > Trade sets... > Solar:
| Tool | Measures | Starter spec |
|---|---|---|
| Panel array area | area | Solar panel array |
| Panels (count) | count | Solar panel |
| DC cable run | length | DC solar cable |
| Inverter | count | Inverter |
| DC isolators | count | Isolator |
| AC cable run | length | AC cable |
| Battery | count | Battery |
| AC isolators | count | AC isolator |
| Roof mounting rail length | length | Mounting rail |
| Conduit run | length | Conduit 25 mm |
Worked example
Worked example: Larkspur Rise Residence
Sheet A3.01, the Larkspur Rise roof plan at 1:50, a hip roof at 25 degrees. For comparison, A3.01 of Kestrel Lane, three hip roofs at 22.5 degrees.
| Measured | Sheet | Quantity |
|---|---|---|
| Larkspur north roof plane, on plan | A3.01 | 85.48 m² |
| Larkspur north roof plane, 25 degree pitch set | A3.01 | 94.31 m² |
| Larkspur whole roof, pitch set (261.27 m² on plan) | A3.01 | 288.28 m² |
| Kestrel north hip ends, three roofs, pitch set | A3.01 | 52.48 m² |
On Larkspur Rise the long north plane gives 94.31 m² of real roof to work with. On Kestrel Lane the ridges run north and south, so each north face is a small hip end of 17.49 m², and the long east and west planes are the ones to look at.
A panel count follows from the plane, the panel size and the clearances.
A fictional demo project, drawn to scale and measured in TrueScale.
Start free trial 30 days, every feature, no card
Common solar takeoff mistakes
- Using plan area for an array. At 25 degrees the Larkspur north plane is 10 percent bigger than its plan. Set the pitch on the area.
- Missing obstructions. Vents, flues and skylights break up a roof plane. Count them with the roofing tools before you lay out the array.
- Cable on plan only. DC cable runs down from the roof to the inverter. Add the drop to the run you measured on the roof plan.
Standards and the NCC
PV arrays are installed to AS/NZS 5033, grid-connected inverters to AS/NZS 4777.1 and battery systems to AS/NZS 5139, with all the wiring to AS/NZS 3000.
Solar takeoff questions
How do I measure roof area for solar panels from a plan?
Trace the roof plane with Panel array area and set the roof pitch on it. TrueScale shows the sloped area of that plane, not just its plan area.
Can I count panels and measure the array?
Yes. Panels (count) clicks each panel on the layout, and Panel array area measures the area it covers, so the two can be checked against each other.
Can I measure DC and AC cable separately?
Yes. DC cable run and AC cable run are separate tools, with Conduit run and Roof mounting rail length in the same set.
Pay once. Own it
One licence has every feature, the Estimate panel and Excel links included. Pay once, own your licence, and take off on TrueScale for Mac too.
Mac: Apple silicon (M1 or newer), macOS 14 or later. Printing, OCR, email, spell check and Link for Excel aren't on Mac yet. What's different on Mac